Previous |  Up |  Next

Article

Title: Comparative analysis of noise robustness of type 2 fuzzy logic controllers (English)
Author: Ontiveros-Robles, Emanuel
Author: Melin, Patricia
Author: Castillo, Oscar
Language: English
Journal: Kybernetika
ISSN: 0023-5954 (print)
ISSN: 1805-949X (online)
Volume: 54
Issue: 1
Year: 2018
Pages: 175-201
Summary lang: English
.
Category: math
.
Summary: Nowadays Fuzzy logic in control applications is a well-recognized alternative, and this is thanks to its inherent advantages as its robustness. However, the Type-2 Fuzzy Logic approach, allows managing uncertainty in the model. Type-2 Fuzzy Logic has recently shown to provide significant improvement in image processing applications, however it is also important to analyze its impact in controller performance. This paper is presenting a comparison in the robustness of Interval Type-2 and Generalized Type-2 Fuzzy Logic Controllers, in order to generate criteria to decide which type of controller is better in specific applications. The plants considered in the experimentation are two benchmark control plants and we report the Integral Squared Error (ISE), Integral Absolute Error (IAE) and Integral Time-weighted Absolute Error (ITAE) performance metrics, and also another important metric reported is the execution time. Based on the experimental results, Fuzzy Logic Controller selection criteria are proposed according to the performance and execution time requirements. (English)
Keyword: interval Type-2 fuzzy logic
Keyword: type-reduction
Keyword: Type-2 fuzzy control
Keyword: Type-2 fuzzy edge detection
MSC: 68T01
MSC: 93C42
idZBL: Zbl 06861620
idMR: MR3780962
DOI: 10.14736/kyb-2018-1-0175
.
Date available: 2018-03-26T19:57:08Z
Last updated: 2020-01-05
Stable URL: http://hdl.handle.net/10338.dmlcz/147157
.
Reference: [1] Abdelaal, M. E., Emara, H. M., Bahgat, A.: Interval type 2 fuzzy sliding mode control with application to inverted pendulum on a cart..In: 2013 IEEE International Conference on Industrial Technology (ICIT), pp. 100-105. 10.1109/icit.2013.6505655
Reference: [2] Amador-Angulo, L., Castillo, O.: Optimization of the Type-1 and Type-2 fuzzy controller design for the water tank using the Bee Colony Optimization..In: 2014 IEEE Conference on Norbert Wiener in the 21st Century (21CW), 2014, pp. 1-8. MR 3558534, 10.1109/norbert.2014.6893876
Reference: [3] Caraveo, C., Valdez, F., Castillo, O.: Optimization of fuzzy controller design using a new bee colony algorithm with fuzzy dynamic parameter adaptation..Appl. Soft Comput. 43 (2016), 131-142. 10.1016/j.asoc.2016.02.033
Reference: [4] Castillo, O., Amador-Angulo, L., Castro, J. R., Garcia-Valdez, M.: A comparative study of type-1 fuzzy logic systems, interval type-2 fuzzy logic systems and generalized type-2 fuzzy logic systems in control problems..Inf. Sci. 354 (2016), 257-274. 10.1016/j.ins.2016.03.026
Reference: [5] Farooq, U., Gu, J., Luo, J.: On the interval type-2 fuzzy logic control of ball and plate system..In: 2013 IEEE International Conference on Robotics and Biomimetics (ROBIO), pp. 2250-2256. 10.1109/robio.2013.6739804
Reference: [6] Fernandes, M. A. C.: Fuzzy controller applied to electric vehicles with continuously variable transmission..Neurocomputing 214 (2016), 684-691. 10.1016/j.neucom.2016.06.051
Reference: [7] Hagras, H.: Type-2 FLCs: A new generation of fuzzy controllers..IEEE Comput. Intell. Mag. 2 (2007), 1, 30-43. 10.1109/mci.2007.357192
Reference: [8] Hannan, M. A., Ghani, Z. A., Mohamed, A., Uddin, M. N.: Real-time testing of a fuzzy-logic-controller-based grid-connected photovoltaic inverter system..IEEE Trans. Ind. Appl. 41 (2015), 6, 4775-4784. 10.1109/tia.2015.2455025
Reference: [9] Hasanien, H. M., Matar, M.: A fuzzy logic controller for autonomous operation of a voltage source converter-based distributed generation system..IEEE Trans. Smart Grid 6 (2015), 1, 158-165. 10.1109/tsg.2014.2338398
Reference: [10] Hoseini, S. A., Labibi, B.: Robust fuzzy controller design with bounded control effort for nonlinear systems with parametric uncertainties..In: 2009 International Conference on Networking, Sensing and Control, 2009, pp. 118-123. 10.1109/icnsc.2009.4919257
Reference: [11] Hassan, S., Khosravi, A., Jaafar, J., Khanesar, M. A.: A systematic design of interval type-2 fuzzy logic system using extreme learning machine for electricity load demand forecasting..Energy Build. 127 (2016), 95-104.
Reference: [12] Kamal, E., Aitouche, A., Kuzmych, O.: Robust fuzzy controller for photovoltaic maximum power point tracking..In: 21st Mediterranean Conference on Control and Automation 2013, pp. 1304-1309. 10.1109/med.2013.6608888
Reference: [13] Karnik, N. N., Mendel, J. M.: Centroid of a type-2 fuzzy set..Inf. Sci. 132 (2001), 1-4, 195-220. MR 1822768, 10.1016/s0020-0255(01)00069-x
Reference: [14] Karnik, N. N., Mendel, J. M., Liang, Q.: Type-2 fuzzy logic systems..IEEE Trans. Fuzzy Syst. 7 (1999), 6, 643-658. 10.1109/91.811231
Reference: [15] Liang, Q., Mendel, J. M.: Interval type-2 fuzzy logic systems: theory and design..IEEE Trans. Fuzzy Syst. 8 (2000), 5-6, 535-550. 10.1109/91.873577
Reference: [16] Liu, J., Zhang, W., Chu, X., Liu, Y.: Fuzzy logic controller for energy savings in a smart LED lighting system considering lighting comfort and daylight..Int. J. Electr. Power Energy Syst. 82 (2016), 1-10.
Reference: [17] Liu, J., Zhang, W., Chu, X., Liu, Y.: Fuzzy logic controller for energy savings in a smart LED lighting system considering lighting comfort and daylight..Energy Build. 127 (2016), 95-104. 10.1016/j.enbuild.2016.05.066
Reference: [18] Mahmoodabadi, M. J., Jahanshahi, H.: Multi-objective optimized fuzzy-PID controllers for fourth order nonlinear systems..Eng. Sci. Technol. Int. J. 19 (2016), 2, 1084-1098. 10.1016/j.jestch.2016.01.010
Reference: [19] Mamdani, E. H.: Application of fuzzy algorithms for control of simple dynamic plant..Proc. Inst. Electr. Eng. 121 (1974), 12, 1585-1588. 10.1049/piee.1974.0328
Reference: [20] Masmoudi, M. S., Krichen, N., Masmoudi, M., Derbel, N.: Fuzzy logic controllers design for omnidirectional mobile robot navigation..Appl. Soft Comput. 45 (201), 901-919. 10.1016/j.asoc.2016.08.057
Reference: [21] Masmoudi, M. S., Krichen, N., Masmoudi, M., Derbel, N.: Fuzzy logic controllers design for omnidirectional mobile robot navigation..Appl. Soft Comput. 49 (2016), 901-919. 10.1016/j.asoc.2016.08.057
Reference: [22] Melin, P., Gonzalez, C. I., Castro, J. R., Mendoza, O., Castillo, O.: Edge-Detection Method for Image Processing Based on Generalized Type-2 Fuzzy Logic..IEEE Trans. Fuzzy Syst. 22 (2014), 6, 1515-1525. 10.1109/tfuzz.2013.2297159
Reference: [23] Mendel, J. M., John, R. I. B.: Type-2 fuzzy sets made simple..IEEE Trans. Fuzzy Syst. 10 (2002), 2, 117-127. 10.1109/91.995115
Reference: [24] Mendel, J. M., Liu, F., Zhai, D.: Alpha-Plane Representation for Type-2 Fuzzy Sets: Theory and Applications..IEEE Trans. Fuzzy Syst. 17 (2009), 5, 1189-1207. 10.1109/tfuzz.2009.2024411
Reference: [25] Ofoli, A. R., Rubaai, A.: Real-Time Implementation of a Fuzzy Logic Controller for Switch-Mode Power-Stage DC - DC Converters..IEEE Trans. Ind. Appl. 42 (2006), 6, 1367-1374. 10.1109/tia.2006.882669
Reference: [26] Premkumar, K., Manikandan, B. V.: Bat algorithm optimized fuzzy PD based speed controller for brushless direct current motor..Eng. Sci. Technol. Int. J. 19 (2016), 2, 818-840. 10.1016/j.jestch.2015.11.004
Reference: [27] Sanchez, M. A., Castillo, O., Castro, J. R.: Generalized Type-2 Fuzzy Systems for controlling a mobile robot and a performance comparison with Interval Type-2 and Type-1 Fuzzy Systems..Expert Syst. Appl. 42 (2015), 14, 5904-5914. 10.1016/j.eswa.2015.03.024
Reference: [28] Singh, M., Kumar, P., Kar, I.: Implementation of vehicle to grid infrastructure using fuzzy logic controller..IEEE Trans. Smart Grid 3 (2012), 1, 565-577. 10.1109/tsg.2011.2172697
Reference: [29] Wati, D. A. R.: Maximum power point tracking of photovoltaic systems using simple interval type-2 fuzzy logic controller based on hill climbing algorithm..In: 2016 International Seminar on Intelligent Technology and Its Applications (ISITIA), pp. 687-692. 10.1109/isitia.2016.7828743
Reference: [30] Wu, D.: On the fundamental differences between interval Type-2 and Type-1 fuzzy logic controllers..IEEE Trans. Fuzzy Syst. 20 (2012), 5, 832-848. 10.1109/tfuzz.2012.2186818
Reference: [31] Zadeh, L. A.: Fuzzy logic $=$ computing with words..IEEE Trans. Fuzzy Syst. 4 (1996), 2, 103-111. MR 1409148, 10.1109/91.493904
.

Files

Files Size Format View
Kybernetika_54-2018-1_11.pdf 3.347Mb application/pdf View/Open
Back to standard record
Partner of
EuDML logo